Demand charge and dispatch decisions  

  RSS
(@gabriel-oliveira)
Trusted HOMER

In the KB I’ve found this article which states that demand charges in HOMER do not impact the dispatch decisions during simulation.

http://usersupport.homerenergy.com/customer/en/portal/articles/2189058-grid-demand-calculation

However, if I define a very expensive peak demand charge for 6pm, for example, the genset is dispatched at peak hour (please find a print attached), which is great.

Is the article outdated?

ReplyQuote
Posted : June 3, 2017 11:30 pm
(@dhiwaakar)
Illustrious HOMER Admin

Hi Gabriel,

 

The dispatch decision is independent of the demand rate as mentioned in the knowledge base article. The generator being dispatched could be because of multiple reasons depending on your system. It could happen if you set a demand limit above which the generator is dispatched as an act of peak shaving. If I can have a look at your HOMER file, I might be able to give you a clearer answer. Thank you.

 

Best,

Dhiwaakar Rajasekaran

ReplyQuote
Posted : June 19, 2017 11:32 am
(@craigmcollinspae)
New HOMER

Does this imply that Homer Pro is incapable of optimizing behind the meter battery and PV capacity for demand charge avoidance? If that's the case, what mechanism is recommend to determine system sizing for demand charge reduction within Homer Pro? I'm thinking that it would require running a simulation with several Annual Purchase Capacity optimization thresholds and then manually comparing the results. 

Any advice?

ReplyQuote
Posted : May 2, 2018 1:27 pm
Share:
  
Working

Please Login or Register